Can you replace a 2 ton AC unit with a 3 ton?

Can you replace a 2 ton AC unit with a 3 ton?

You can upgrade a two ton up to a three ton but no higher. I had a 2 ton unit and when it went out I upgraded to a 2 1/2 ton. Go too high and it will short cycle meaning it will turn on and off more often and at shorter intervals. Not really cooling the air enough and it will feel muggy.

Can you Oversize an evaporator coil?

You cannot oversize your evaporator coil because the AC won’t function properly and might get broken. The coils should be of the same size as the other to avoid the rise of complicated problems.

Will a 3 ton coil work with a 2.5 ton condenser?

I have the exact situation in my house as you mentioned…a 2.5 ton AC with a 3 ton coil. You won’t notice any improved performance, but the SEER of the total system will be somewhat improved.

Can you put a 2.5 ton condenser with a 2 ton coil?

To put a 2 ton coil on a 2.5 ton compressor unit. You sure will pay for it in the electric it will use.

How much should a 2 ton AC unit cost installed?

Average AC Unit Prices by Size or Capacity

Central AC Unit Size AC & Coil AC & Coil Installed Cost
1.5 Tons, 18,000 btu $940 $1,895
2 Tons, 24,000 btu $1,490 $2,690
2.5 Tons, 30,000 btu $1,525 $2,695
3 Tons, 36,000 btu $1,650 $2,990

How big of a house will a 2 ton AC unit cool?

ZONE 1 ZONE 2
1.5 Tons 600 – 900 sf 600 – 950 sf
2 Tons 901 – 1200 sf 951 – 1250 sf
2.5 Tons 1201 – 1500 sf 1251 – 1550 sf
3 Tons 1501 – 1800 sf 1501 – 1850 sf

Can I use a 3 ton condenser with a 4 ton coil?

Registered. I have a 3 ton condenser with a 4 ton coil and I haven’t had any issues with it. I do live in a dry climate, so it’s not an issue. If you live in a more humid area, I’d suggest not over sizing the coil.

Can a 5 ton coil keep up with a 4 ton condensing coil?

For example, if a house requires a 5-ton system, a contractor might install a 5-ton evaporator coil and a 4-ton condensing unit. “According to some people, you do get a little bit more efficiency out of that. The problem I have seen out in the field is that the unit runs a lot longer, because it’s not able to keep up with the load.

Can a condenser coil be replaced with a whole AC unit?

The condenser coil or the “outside coil” These coils are both housed within the same AC unit but are still separate components that must work closely together to cool your home. That said, replacing just one of these coils could cause major problems for your unit. Let’s take a closer look at when replacing the entire unit is more cost effective.

Do you have to replace the evaporator coil?

The evaporator coil is a key component in the operation of your central ac, and it must be matched to the outdoor condensing unit in both size (btu capacity) and refrigerant type. The factors below will have the greatest impact on cost of AC evaporator coil replacement.

Can a 3.0 ton heatpump have a 4 ton coil?

My 3.0 ton heatpump is installed with a 4.0 ton coil and TXV. Yeah, it is normal. It just means your designer better know what he is doing or there can be problems. My 3.0 ton heatpump is installed with a 4.0 ton coil and TXV.

Can a 2.5 ton Trane have a 3 ton coil?

2.5 with 3 ton coil is not uncommon. I’ve seen 4 ton Tranes with an option of 5 ton coil. Bottom line is when designing a system you have to consult manufacturer guidlines and use condenser, evap combos Approved by manufacturer to get the results you need for the specific job.

The evaporator coil is a key component in the operation of your central ac, and it must be matched to the outdoor condensing unit in both size (btu capacity) and refrigerant type. The factors below will have the greatest impact on cost of AC evaporator coil replacement.

The condenser coil or the “outside coil” These coils are both housed within the same AC unit but are still separate components that must work closely together to cool your home. That said, replacing just one of these coils could cause major problems for your unit. Let’s take a closer look at when replacing the entire unit is more cost effective.

My 3.0 ton heatpump is installed with a 4.0 ton coil and TXV. Yeah, it is normal. It just means your designer better know what he is doing or there can be problems. My 3.0 ton heatpump is installed with a 4.0 ton coil and TXV.