How do I delete a block diagram in LabVIEW?
How do I delete a block diagram in LabVIEW?
On the Source File Settings page of the Source Distribution Properties dialog box, remove the checkmark from the Use default save settings checkbox and place a checkmark in the Remove block diagram checkbox to ensure that LabVIEW removes the block diagram.
How do you clean up LabVIEW?
There are three ways to perform a diagram cleanup:
- Click the Cleanup Diagram button on the block diagram toolbar.
- Select Edit»Cleanup Diagram from the block diagram menus.
- Use the Cleanup Diagram shortcut key by holding
What is block diagram in LabVIEW?
The block diagram contains the graphical source code of a LabVIEW program. The concept of the block diagram is to separate the graphical source code from the user interface in a logical and simple manner. Front panel objects appear as terminals on the block diagram.
How do I save a block diagram in LabVIEW?
To print the VI, use the following steps:
- Open the VI you want to generate a block diagram image for.
- Go to File»Print.
- Choose the VI or VIs you want to print.
- If you want just the image of the block diagram, choose Icon, description, panel and diagram.
- If you choose VI documentation, ensure Block diagram is checked.
How do I clean up wire in Labview?
Right click on a messy wire and select “Clean Up Wire.” This will automatically rearrange the wire so that there are fewer bends and it is easier to tell where it is going.
How do I edit a block diagram in LabVIEW?
To change this configuration you can just go to VI toolbar a select Operate>>Change to Edit Mode (or press CTRL-M)
How is a diagram different from the front panel in LabVIEW?
The front panel includes controls and indicators. The block diagram includes wires, icons, functions, possibly subVIs, and other LabVIEW objects.
How do I clean up wires in LabVIEW?
What is the keyboard shortcut for quickly copying something in LabVIEW?
DOWNLOAD (Windows Only)
Keyboard Shortcut | Description |
---|---|
Ctrl-X | Cuts selected objects. |
Ctrl-C | Copies selected objects. |
Ctrl-V | Pastes last cut or copied objects. |
Help |
How do you edit a block diagram?
Click on a block diagram template to view it, and click the Edit button to start editing. The rest can be found in the block diagram maker.
How do I edit LabVIEW?
You cannot edit a LabVIEW executable. In order to edit a LabVIEW application, it is necessary to have the LabVIEW Project where it was developed. In the LabVIEW project you can make all necessary changes to the VIs and then build the executable once again. However, there is no way to edit an executable directly.
What are the front panel and the block diagram in LabVIEW?
The front panel includes controls and indicators. The block diagram includes wires, icons, functions, possibly subVIs, and other LabVIEW objects. Every VI displays an icon in the upper right corner of the front panel window and block diagram window.
How to remove a block diagram from Vis-LabVIEW?
Create a source distribution. On the Source File Settings page of the Source Distribution Properties dialog box, remove the checkmark from the Use default save settings checkbox and place a checkmark in the Remove block diagram checkbox to ensure that LabVIEW removes the block diagram.
Can you remove a block diagram from a VI without compiled code?
Note You cannot remove a block diagram from a VI without compiled code. If you place a checkmark in the Remove compiled code checkbox on the Additional Exclusions page, LabVIEW dims the Use default save settings checkbox on the Source File Settings page. Build the source distribution to create a copy of the VI without its block diagram.
Is it possible to remove the block diagram Source code?
You can remove the block diagram source code from a VI so other users cannot edit the VI if you distribute VIs to other computers or other users. You also can assign password protection to a block diagram so the block diagram is still available if users enter a password, but a password provides less security than removing the block diagram.
Can you unlock a VI in LabVIEW 5.0?
In LabVIEW 5.0 and later, it is possible to password protect a VI, which allows you to distribute the VI without giving access to your source code. Be aware that if a VI is password-protected and you do not have a password for it, there is no way of unlocking the VI. For security reasons, National Instruments cannot unlock password-protected code.