How do you reset a Pumptec no load sensor?
How do you reset a Pumptec no load sensor?
When Pumptec detects that the motor load has dropped below a preset level for over 4 seconds, it will interrupt power to the motor and display the tripped condition light. To reset Pumptec manually, turn off the power supply for 5 seconds, and then turn it back on.
What does the load light mean on a Pumptec?
Solid Load Light Pumptec has detected a dry well or underload condition. A. Make sure the pump and motor are matched correctly. B. Check for a blocked pump intake or stuck check valve.
How do I reset my Pumptec?
Press and hold in the reset button on the bottom of the Pumptec-Plus enclosure until the green, yellow, and red lights blink alternately. This should take approximately 10 seconds. You will hear the Pumptec-Plus contactor engage and the motor should start. Release the reset button.
What does a Pumptec do?
Pumptec is a microcomputer-based device that monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Pumptec interrupts power to the motor whenever the load drops quickly or below a preset level.
How do you calibrate a pump saver?
The PumpSaver®Plus can also be calibrated while the pump is running. Turn the RESTART DELAY/ CALIBRATION knob to CAL. while pumping. Wait for the pump to turn off (approximately 10 seconds), then adjust the RESTART DELAY/ CALIBRATION knob to the desired setting.
How do I protect my water pump?
The most reliable way to protect your pump against dry running is to install external conductivity probe with a switch. This system shuts off the pump before the pump draws in air, providing 100% protection against damage.
How do you bypass Pumptec?
Bypass Pumptec by connecting L2 and the motor lead with a jumper. If motor does not run, the problem is not Pumptec. D. Check that Pumptec is installed between the control switch and motor.
What is the HP rating of a Franklin jet pump?
Indicator lights on the cover provide complete system status. HP Rating: Franklin 4″ single-phase 2-wire and 3-wire induction-run submersible motors up to 1 HP and capacitor-run motors up to 1-1/2 HP Note: Pumptec is not designed to be used on permanent split capacitor motors or on jet pumps.
What do you need to know about the pumptec?
Exclusively designed for Franklin QD Relay Control Boxes, QD Pumptec is a solid state sensing device that monitors motor load and incoming power to automatically shut off a Franklin single-phase, 3-wire motor when related fault conditions are detected.
What are the protective devices on Franklin Motors?
Franklin’s single-phase protective devices have been exclusively designed to help extend the life of Franklin motors. They monitor and diagnose motor load to prevent pump or motor failure due to adverse conditions such as low-flow wells, pump damage, clogging, bound pump, or power mishaps.
What is the toll free number for Franklin Electric?
Phone Franklin’s toll-free Technical Service Hotline for answers to your installation questions. When you call, a Franklin expert will offer assistance in troubleshooting your pump protection system and provide immediate answers to your motor application questions. FRANKLIN ELECTRIC TECHNICAL SERVICE HOTLINE (800) 348-2420 225468103Rev. 206-16