Easy tips

What to do if your AC blower is not working?

What to do if your AC blower is not working?

Disconnect cables to motor and resistor. Remove hose from motor, it should just pull off with little effort. Unscrew motor and resistor. Screw new motor and resistor in. Connect hose to motor. Connect cables to motor and resistor. Turn on car and test AC. Thanks for watching! Loading…

What was the problem with my 2003 Trailblazer?

This 2003 Chevrolet Trailblazer came in with the complaint that the blower would not work on any speed and that the Brake and ABS lights stay on. Since I have seen this problem before, I knew right where to go to test. then ignition switch.

How do you plug in a blower blower?

Plug the wiring harness back up to the switch. Positioned the rest of the wiring back into the retainer on the side of the switch. Cranked the engine and checked the blower and all is well. Time to finish installing the rest of the parts.

Disconnect cables to motor and resistor. Remove hose from motor, it should just pull off with little effort. Unscrew motor and resistor. Screw new motor and resistor in. Connect hose to motor. Connect cables to motor and resistor. Turn on car and test AC. Thanks for watching! Loading…

Why does my blower motor not come on?

You should be able to find this relay or sequencer by tracing the blower motor wires back to the relay or sequencer. If power is going into the sequencer or relay and not coming out when the 24 volts are applied then you have a relay or sequencer problem and the sequencer or relay will need to be replaced to get your blower running right again.

Are there any problems with the Dodge blower motor?

And after doing a little research I discovered that a lot of other people are going through the same thing. Here we’ll discuss the common issue of Dodge blower motor problems and the recommended steps to help prevent melted connectors, damaged wire harnesses and repeat failures of the blower resistor.

What are the symptoms of a failed blower motor resistor?

Blower motor resistor problems. Problems with a blower motor resistor are common in many cars. The most common symptom of a failed blower motor resistor is when the heater fan only runs at high speed and doesn’t work at low speeds.

What does it mean if your blower motor is not working?

Average rating from 849 customers who received a AC is not working Inspection. The blower motor resistor is an electrical component that is a part of the vehicle’s heating and air conditioning system. It is responsible for controlling the blower motor’s fan speed.

And after doing a little research I discovered that a lot of other people are going through the same thing. Here we’ll discuss the common issue of Dodge blower motor problems and the recommended steps to help prevent melted connectors, damaged wire harnesses and repeat failures of the blower resistor.

What should I do if my blower fan wont come on?

You will need to test with a voltmeter and see if your fan motor is getting the required 110 to 125 volts AC out of your control board to start the motor. I would suggest setting your thermostat to the “Fan ON” position. You should be getting 120 volts out of the control board.

What are the symptoms of a bad blower motor relay?

3. Melted relay. Another more serious symptom of a problem with the blower motor relay is a burned or melted relay. Relays are exposed to high current loads and can sometimes get hot when they develop problems.

Why is my car AC not blowing or car fan not working?

It sounds like your blower motor or fan is damaged. The noise you heard was probably the fan blades hitting the side of your ventilation ducts and it suddenly stopped when either the motor failed or the fan finally got stuck. Replacing the blower motor and possibly fan should get you back to having AC!

What causes an air conditioner motor to stop working?

Another common problem that can be caused by air conditioner blower motors is the formation of ice, or icicles, on, or around the air conditioner unit and vents.

How can I tell if my AC blower motor is broken?

Air Conditioner Blower Motor Won’t Turn On. If you turn on your air conditioning system and find that there is no air blowing out of the AC unit, or no buzz of the blower fan motor, then it is possible the AC blower motor has an issue. This is one of the most common and easy ways to know if your air conditioner blower motor is broken or not.

Why is the air conditionor not working?

Air conditioners can create a lot of water because they remove moisture from the air. To get rid of this, they have a [usually plastic] drain pipe that comes out of the side of the air handler. Over time, algae can block this pipe and, when it does, the AC won’t work.

Why is your air conditioner not working?

When your air conditioner suddenly stops working, it can be cause for alarm or it can be something as simple as a blown fuse or tripped circuit breaker . While many problems with your air conditioner will require a professional technician to repair the issue, we find that sometimes a homeowner can fix simple problems with a little troubleshooting.

Why is my air conditioning fan not working?

There are four specific reasons why you might find your air conditioner fan not working. The circuit breaker has tripped. The disconnect box is damaged. The primary motor control is disabled. The motor itself is compromised.

Why is my AC heater not working?

The potential issues here vary whether your heating has gone out or your car’s AC system is on the fritz. Common reasons for the heating system not to work include the following: Low coolant. Air in the coolant system. Malfunctioning heater core. Failed (or failing) thermostat.

Why does my AC only work when I Am driving?

Your AC only working while you are driving might have to do with a low refrigerant level, or it may be an indication that your electric fans are not turning on. Try checking the fuse and relays for your fans to make sure they are turning on when you turn the AC on. My AC was working fine til today I just started my car an the AC just shut off.

Can a blower fan be turned on in cool mode?

If the Y terminal is energized, it turns on the a/c outside unit, but not the blower fan. Typical thermostats will energize the G terminal when in cool mode, or when the fan is turned to manual “always on” mode. It sounds to me like the G terminal is not being energized.

Why is my front AC blower not working?

I’ve seen many posts from people whose front AC blower would stop occasionally. My wife would kick the wires under the glove compartment and it would start again. It finally failed altogether. Following the advice from other owners, I replaced the blower motor resistor. That didn’t help.

Why is my air conditioner not starting up?

Another common problem with the air conditioner blower motor not starting up, is caused by overheating. Most AC systems are designed to work within a large range of temperature variants and environments, however due to numerous causes, the air conditioner is still prone to overheating.

What causes an air conditioner fan to fail?

A dirty blower motor fan can cause the blower motor to fail and cause ice build up. If this is your issue, then the solution, in most cases, is not too difficult in most cases and simply requires you to open up the air conditioner unit, remove the fan from the blower motor assembly and thoroughly clean it, in warm soapy water if possible.

How does an air conditioner blower motor work?

As explained in the HVAC Blower Motor Guide, an air conditioner blower motor and assembly is basically the fan inside the air conditioning system that forces the cooled air, via the AC cooling coil, through the vents and into the room space that is being conditioned.

Average rating from 849 customers who received a AC is not working Inspection. The blower motor resistor is an electrical component that is a part of the vehicle’s heating and air conditioning system. It is responsible for controlling the blower motor’s fan speed.

What are the symptoms of a bad heater motor resistor?

Symptoms of a Bad or Failing Heater Blower Motor Resistor. 1 1. Blower motor stuck on one speed. A common symptom of a faulty blower motor resistor is a blower motor that is stuck on one setting. The blower 2 2. Blower motor does not work on certain settings. 3 3. No air from the vehicle’s vents.

Why does my AC heater motor stop working?

The heater – AC blower motor may stop working at one or more speeds due to a faulty blower motor resistor block.

What to do if your AC or heater is not blowing?

If your Blower Motor for the AC or Heater suddenly stopped blowing, look here first, it might save you several dollars. Situation, we have a friend that owns a 2017 Chevy Trax LT, she is a nurse who works with my wife, single mom and on a single mom budget.

Is the AC / heater blower motor working on Level 4?

AC/Heater blower motor only works on level 4 (highest speed). haven’t fixed it yet. Blower motor only worked on settings 0 and 4. If set in between, freon continues to circulate through the system without any cool air being blown into the cabin.

Why is my air blower not working on my truck?

Just take the air filter cover off and you can see the box shaped black ground wire attached by a bolt to the bumper. Un bolt the ground wire and clean the contacts try the blower and it should work! I have had this problem 3 times since I bought the truck in 2004. The blower would quit working on all speeds except high

Can you change the motor on an air conditioner blower?

There are blower motors that are reversible with a simple wiring change. The bracket, which is in the existing unit, may not be able to be reused. That will necessitate a new bracket that will mount the motor properly. Sometimes it also necessary to change the blower wheel.

How to replace a blower resistor and motor?

Easy video on how to replace blower resistor and motor with 1 screw driver and in about 10min. Remove glove box, pop bottom panel off to gain motor access. Disconnect cables to motor and resistor. Remove hose from motor, it should just pull off with little effort. Unscrew motor and resistor. Screw new motor and resistor in. Connect hose to motor.

What does a blower motor do in a HVAC system?

The blower motor is a component in your HVAC system that blows the conditioned air through the vents in your home. It takes the cool air created by your air-conditioner and circulates it throughout your indoor space to ensure that the temperature reaches the level dictated by the thermostat.

How much does it cost to replace a blower motor in an AC unit?

Replacing the blower motor in an AC unit costs the same as a furnace since they share this mechanism. Expect to pay $250 to $800 on average. You might spend up to $2,000 depending on the brand. Don’t confuse the blower motor with the AC condenser fan which sits inside your outdoor air conditioning unit.

Where is the AC blower motor in the House?

The AC blower motor is in the air handler within your home. It’s usually in the basement, a utility closet or the attic. What is an AC blower motor? An AC blower motor is the same thing as one used in a furnace.

What should I do if my air conditioner blower motor fails?

Most HVAC supply houses or even OEM stores do not sell to the general public. There are many reasons for this, but it is partly to encourage competent repairs by a skilled technician when the system fails. As always, it is always recommended to add a new capacitor, especially if replacing a bad blower motor.

What’s the best way to replace an air conditioner motor?

There are several different types of air conditioner motors. When dealing with anything electrical, the best replacement is an exact replacement. There is a contradiction to that phrase. If you have a shaded-pole air conditioner blower motor in your air handler, I recommend replacing it with a PSC motor.

What happens if a heater blower has no power?

A blower motor without power will not be able to produce any air pressure, and as a result the heating and air conditioning system will be left with no air coming from the vents.

What are the signs of a bad heater motor?

Common signs include the car’s heater not working or getting stuck on a certain speed, or something getting jammed in the blower motor. 1. Blower motor stuck on one speed 2. Blower motor does not work on certain settings 3. No air from the vehicle’s vents Average rating from 130,908 customers who received a Vehicle Engine Cooling Inspection.

Can a Dodge Ram blower motor work on the AC?

Dodge Ram blower motor won’t work on the heater and AC. There is no power going to the blower motor, fire reducer or to switch. Fuses are good, relays are good but it will not heat or cool the truck. How to fix this? Show More

What happens if heater blower motor does not work?

Therefore, if major problems in the heating and air conditioning system fail, as if the power supply to the motor was completely cut off due to overheating or corrosion, the motor will simply not work, which in turn will render the entire heating and air conditioning system unusable, as no air will flow through the vehicle’s air vents. 2.

Why does my air conditioner blower not come on?

The blower is suppose to run , according to the manual, for 45 seconds after the thermostat is satisfied also shutting down the outside unit/compressor. Well mine don’t. When compressor shuts off with a satisfied thermostat my blower motor shuts off mediately too.

What causes a bad or failing blower motor relay?

Blown fuses. One of the first symptoms of a bad or failing AC blower motor relay is a blown AC blower motor relay circuit fuse. If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current…

What to do if your Dodge Nitro heater is not working?

Disconnect the Neg (-) battery cable, and isolate it! You don’t want the airbags to go off accidentally. On the passenger side, remove the lower shield (called a silencer, it is a soft flexible insulation type of material) at the bottom under the dash. This will give you more clearance.

Why does my AC Heat fan make a clicking noise?

If your interior AC/ Heat fan (blower motor) is making noise like a card in a bicycle spoke, then you probably just need to clean out the blower motor which is easy and free. Leaves and debris gets in the blower motor and make a clicking noise when the fan hits the leaves.

Disconnect the Neg (-) battery cable, and isolate it! You don’t want the airbags to go off accidentally. On the passenger side, remove the lower shield (called a silencer, it is a soft flexible insulation type of material) at the bottom under the dash. This will give you more clearance.

Easy video on how to replace blower resistor and motor with 1 screw driver and in about 10min. Remove glove box, pop bottom panel off to gain motor access. Disconnect cables to motor and resistor. Remove hose from motor, it should just pull off with little effort. Unscrew motor and resistor. Screw new motor and resistor in. Connect hose to motor.

Why does my blower not come on neither heat or cooling mode?

Hello, I have heat pump unit with a backup auxiliary heat. My blower will not come on neither heat or cooling mode. Blower will no running on neither auto or fan. I’d jumped the motor and is working. My capacitor and transformer is also good too.

Why does my air conditioner fan not come on?

Top 10 Reasons Why the Blower Fan Motor will not come on. Furnaces, Air Conditioning and Heat Pumps • Arnold’s Service Company, Inc. Top 10 Reasons Why the Blower Fan Motor will not come on. Furnaces, Air Conditioning and Heat Pumps

When do you Know Your air conditioner is not working?

If you turn the thermostat to “Cool” and absolutely nothing happens, please see Central AC Not Working At All. This information will also guide you through checking the air handler, clearing the condensate drain, and checking the outdoor compressor. If you can hear the AC running but it isn’t blowing air, please see Air Conditioner Not Blowing Air.

What causes the AC blower not to come on?

A common problem behind an air conditioner blower not starting includes overheating, which keeps the motor from running. Let your air conditioner rest and cool down for a while before trying to turn it on again; if the motor works at that point, overheating is probably the problem.

Why is my AC compressor not working?

Some of the most common reasons AC compressors stop working include: Dirty condenser coils. Blocked suction lines. Low refrigerant charge. Incorrect suction line size. Too much refrigerant. Electrical problems. Contaminants in the system.

Why is my AC not working at all?

How To Remedy Issues In Your Central Air Conditioning Capacitor problems. A capacitor stores up energy that provides power to your air conditioner’s fans. Contactor problems. An air conditioner contactor is an electrical switch that controls the compressor and condenser fan motor. Burnt out motor. Loose or broken belt. Unit not receiving power.

Why is your AC not working?

When your air conditioner suddenly stops working, it can be cause for alarm or it can be something as simple as a blown fuse or tripped circuit breaker . While many problems with your air conditioner will require a professional technician to repair the issue, we find that sometimes a homeowner can fix simple problems with a little troubleshooting.

What causes a blower motor to stop working?

In a situation where the motor doesn’t work on any speed, the most likely causes are: a blown power supply fuse, a bad motor ground connection, bad motor speed control module or a failed motor. On all systems, a failed blower motor is least likely. Blower motors generally don’t fail out of the clear blue.

How do you troubleshoot a blower motor resistor?

This can be annoying, but troubleshooting is easy. If you start at the blower motor, and check resistance in the circuit, you will find the problem in no time. Power supplied from the fuse panel passes through the switch to the blower resistor assembly.

3. Melted relay. Another more serious symptom of a problem with the blower motor relay is a burned or melted relay. Relays are exposed to high current loads and can sometimes get hot when they develop problems.

Blower motor resistor problems. Problems with a blower motor resistor are common in many cars. The most common symptom of a failed blower motor resistor is when the heater fan only runs at high speed and doesn’t work at low speeds.

How can I tell if my blower motor has a problem?

Press and hold the OFF button and within 10 seconds press and release the Window Defogger button five times. The system enters the self-diagnostic mode and at the end of it, if there is a problem, the fault code will be displayed on the display.

Where does the power transistor go in a blower motor?

The power transistor has 4 wires: two come from the climate control system control unit, one is the ground, one goes to the negative terminal of the blower motor. The service manual advises measuring the voltage at the blower motor, then if not OK, at the power transistor and so on.

How is the speed of the blower motor controlled?

The electronic module that controls the speed of the blower motor is called a blower motor control module. In some cars, the blower motor has only 4 or 5 fixed speeds. In this case, the speed of the blower motor is controlled by a blower motor resistor.

What happens if you have a bad blower motor?

The blower motor is the component responsible for pushing air through the vents of your vehicle’s heating and air conditioning systems. Without it, the AC system will not be able to circulate any heated or cooled air.

The blower motor is the component responsible for pushing air through the vents of your vehicle’s heating and air conditioning systems. Without it, the AC system will not be able to circulate any heated or cooled air.

Air Conditioner Blower Motor Won’t Turn On. If you turn on your air conditioning system and find that there is no air blowing out of the AC unit, or no buzz of the blower fan motor, then it is possible the AC blower motor has an issue. This is one of the most common and easy ways to know if your air conditioner blower motor is broken or not.

Another common problem that can be caused by air conditioner blower motors is the formation of ice, or icicles, on, or around the air conditioner unit and vents.

What to do if your central air blower won’t work?

If the thermostat, breakers and access panel doors check out, the blower motor itself may have failed. Motors have a long useful life, but they do seize up or burn out in time. You may want to call a repair person at this point. A qualified air conditioning expert can test the motor, find the proper replacement and install it.

As explained in the HVAC Blower Motor Guide, an air conditioner blower motor and assembly is basically the fan inside the air conditioning system that forces the cooled air, via the AC cooling coil, through the vents and into the room space that is being conditioned.

What to do if your blower switch goes bad?

I went through and replaced all the major culprits.. a new blower motor, new blower resistor & harness, and new blower relay. Wouldn’t you know, still nothing. What possibilities are left? I was wondering if the switch itself (in the dash) can go bad.. I don’t get this. Great timing in the summer heat!

Do you need a volt meter for a blower motor?

I don’t have a volt meter, unfortunately. The blower motor fuse (and possibly fan switch in the dash) are two things that would be within my capability at least.

Where are the fuses on a blower motor?

The blower motor fuse (and possibly fan switch in the dash) are two things that would be within my capability at least. should be in the same fuse box where the relay is.lid should be marked for fuse positions and relay positions on top of the lid or under it.check the fuses first before replacing anything else!

Are there any recalls on the BMW blower motor?

BMW driver says blower motor and PCV valve heater recalls are useless without replacement parts. BMW driver says blower motor and PCV valve heater recalls are useless without replacement parts.

What should I do if my gas fireplace blower is not working?

A loose wire or similar minor issue can often be fixed in a few minutes without calling a repair technician. Turn off the gas valve that controls the fireplace burners and wait for the insert to cool. Shut off the circuit breaker for the motor that operates the blower. Remove the screws holding the housing on the blower motor, using a screwdriver.

What should I do if my electric heater doesn’t work?

If playback doesn’t begin shortly, try restarting your device. An error occurred. Please try again later. (Playback ID: qQsR763xdcPX2ccz)

What would cause my heater not to work?

CAUSE: Another cause of electric heater not working could be an issue with the electric cord. An electric cord can go faulty and may stop working which in turn effects the working of the heater.

Why is my heater not working in my house?

The most common culprit for your heaters not working is a faulty thermostat. These clever yet very simple and cheap contraptions regulate the water circulation on initial startup. They’re easy to purchase and simple to replace if you have a little mechanical knowledge.

What to do if car heater is not working?

Check the heater core temperature. Lift the hood and check the temperature around where the heater core hoses enter the heater core box. The safest way to do this is with a non-contact infrared thermometer. If one hose is the same temperature as the coolant and the other hose is cold, there may be a blockage in the heater core.

Why does heater stop working?

A heater can stop working for a number of reasons, including: •A low antifreeze/water level in the radiator due to a leak in the cooling system. •A bad thermostat that isn’t allowing the engine to properly warm up. •A blower fan that isn’t working properly.

Why does my air conditioner fan won’t start?

This article series describes in detail the testing and diagnosis of problems with air conditioning fans and with forced warm air heating blower fans found in the air handler or AHU. When the blower fan won’t start the problem could be something as simple as a blower compartment door that is not fully closed, or a clogged condensate drain.

What happens when a central air blower does not start?

The blower motor starts, turning fan blades that circulate cold air from the evaporator coils, through the home’s ductwork and into each room. If the blower motor fails to start, nothing happens. The living spaces gets uncomfortable as the cooling cycle stalls. Most thermostats control both central air and central heat.

Why is my Ford Five hundred air conditioner not working?

When attempting to turn on the air condition, many ford five hundred drivers notice only warm air coming from the… You may not realize there’s a refrigerant leak until the air conditioner stops blowing cold. Refrigerant may slowly leak out of the system over days, weeks or even years.

Common signs include the car’s heater not working or getting stuck on a certain speed, or something getting jammed in the blower motor. 1. Blower motor stuck on one speed 2. Blower motor does not work on certain settings 3. No air from the vehicle’s vents Average rating from 130,908 customers who received a Vehicle Engine Cooling Inspection.

A blower motor without power will not be able to produce any air pressure, and as a result the heating and air conditioning system will be left with no air coming from the vents.

What are the symptoms of a bad blower motor resistor?

Another common symptom of a faulty blower motor resistor is a a blower motor that does not function on certain settings. If the blower motor resistors’ internal components fail it may cause the blower motor to malfunction, or not function at all on one or more of the settings.

Why is my blower motor stuck on one speed?

Blower motor stuck on one speed A common symptom of a faulty blower motor resistor is a blower motor that is stuck on one setting. The blower motor resistor is the component directly responsible for controlling the blower motor fan speed. If the resistor shorts or fails, it may cause the blower motor to remain stuck on one fan speed.

Why is my air conditioner not working on my Ford F150?

If your Ford F150 isn’t keeping you cool, we’ve outlined some of the most common reasons why this might be happening. The only thing that the air conditioning system has in common with the heater is that they both use the climate controls and the blower motor.

How do you fix a blower motor on a car?

Disconnect the electrical connector at the blower motor and jumper power and ground to the motor, bypassing all the speeds controls. Run a fused jumper from the battery to the power side of the motor and connect a temporary grounding jumper to the other motor terminal.

If your Ford F150 isn’t keeping you cool, we’ve outlined some of the most common reasons why this might be happening. The only thing that the air conditioning system has in common with the heater is that they both use the climate controls and the blower motor.

What causes a fuse to blow on a blower motor?

If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.

How can I tell if my AC unit is having a problem?

You can check for this problem by listening to the AC unit when it is turned on. If you can hear the blower motor running but no air coming out of the unit, then it is possible the problem is with the fan belt itself.

What happens when a fuse blows on an AC unit?

If the voltage increases beyond its amperage capacity, the fuse blows. Essentially, when the fuse blows, it cuts the power supply to the unit and thereby saving the unit from any further damage. If you suspect that your AC may have blown a fuse, the first thing you shall notice is that the outside unit of your AC is not doing anything.

How can I tell if my AC unit has blown a fuse?

If you suspect that your AC may have blown a fuse, the first thing you shall notice is that the outside unit of your AC is not doing anything. You may hear a minor humming sound, but that is the extent of it. The humming sound is produced because, despite no power, the furnace keeps asking the AC to run.

Where is the blower fuse on a Dodge?

Dodge owners manual shows the 40 amp blower fuse, #25, but does not mention any blower relay in the PDC. All the relays in the PDC have designated legends on the cover, but none indicate they are for the front blower relay. Haynes also states this blower relay is powered via a fuse in the junction box from under the dash, #12, 10 amp.

Author Image
Ruth Doyle