Air Door Actuators Cables were used in older models to control mode and blend doors. These were replaced with vacuum motors and electric actuators. As they wear, the endpoints change, or the plastic gears inside the actuator break and strip. When replaced, they typically require calibration.

How to calibrate Yukon XL blend door actuator?

2003 yukon xl. how do i calibrate the blend door actuator and also the recircultion door actuator? need help its hot. Remove the HVAC/ECAS fuse for a minimum of 10 seconds. Re-install the HVAC/ECAS fuse. Start the vehicle. Wait 40 seconds for the HVAC control module to re-calibrate. Verify that no DICs have set as current DICs.

When do HVAC actuators need to be calibrated?

Actuator Calibration Starting in 2001, whenever the battery is disconnected or when replacing any of the HVAC actuator motors (mode door or temperature blend) the HVAC system will have to go through a relearn or calibration process. Failure to allow sufficient time to calibrate can lead to the

How to recalibrate the HVAC actuator in a GM Truck?

For manual systems it does not matter where the a/c controls are set but if you feel the need to do something, turn the blower switch on (I prefer speed 3) and set the temperature sliders about .5″ to .75″ from full cold. For auto systems, press the auto button, with the key on. Turn the ignition off.

How to perform the actuator recalibration procedure on a Cadillac?

The topic of how to perform the actuator recalibration procedure on Chevrolet , GMC and Cadillac Trucks and SUVs has become an ever increasing topic of discussion.

2003 yukon xl. how do i calibrate the blend door actuator and also the recircultion door actuator? need help its hot. Remove the HVAC/ECAS fuse for a minimum of 10 seconds. Re-install the HVAC/ECAS fuse. Start the vehicle. Wait 40 seconds for the HVAC control module to re-calibrate. Verify that no DICs have set as current DICs.

How to calibrate the blend door actuator motor?

Blend Door Actuator Motor Calibration 1 15 in the fuse box next to the battery. 2 Remove the fuse and wait 1-2 minutes for any capacitive charges in the system to dissipate. 3 Replace the fuse. 4 Turn the ignition key to the on position. You can now watch the motors move as the system goes through the calibration routine.

Where is the fuse on a blend door actuator?

Open hood (bonnet for the RHD guys) and locate fuse #15 in the fuse box next to the battery. Remove the fuse and wait 1-2 minutes for any capacitive charges in the system to dissipate. Replace the fuse. Turn the ignition key to the on position. You can now watch the motors move as the system goes through the calibration routine.

Actuator Calibration Starting in 2001, whenever the battery is disconnected or when replacing any of the HVAC actuator motors (mode door or temperature blend) the HVAC system will have to go through a relearn or calibration process. Failure to allow sufficient time to calibrate can lead to the