Will ecm cause fuel pump to not work?
Will ecm cause fuel pump to not work?
If you do obtain this reading and the ecm will not make the fuel pump operate, replace the pump. If you do not obtain the correct voltage, the problem is somewhere between the fuel pump electrical connection and the ecm. You might be better off to consult a professional mechanic in this case.
Does ecm control fuel pump?
The ECM powers the pump through the fuel pump relay as long as reference pulses are received from the distributor, which means as long as the engine is running. Loss of oil pressure won’t stop the engine.
Is there an ECM signal to the fuel pump relay?
The fuel pump relay works as it should. I always have power to Pin 30. I believe the ECM tells the relay to work via the green/black wire to Pin 85. This should happen for 2 seconds when the key is turned on. I have tested this when the issue is occurring and have confirmed that no signal is being sent from the ECM.
Is there no power to the fuel pump?
No power to the fuel pump and the fuel relay is not getti… Q: No power to the fuel pump and the fuel relay is not getting power. My car has 190000 miles.
Why is the fuel pump relay not turning on?
The ECM controls the fuel pump relay and this relay will only energize when commanded on. Does the check engine light come on; if not, then the ECM is not turning on. Do all the other combination meter warning lights come on?
What kind of connector for fuel pump relay?
Grounds are usually almost ring connectors. A ring connector is a round connector that a fastener goes through and holds the ring connector securely this way. You might want to get some electronic connector cleaner at your local auto parts store. It comes in a spray can and is made by CRC.
The fuel pump relay works as it should. I always have power to Pin 30. I believe the ECM tells the relay to work via the green/black wire to Pin 85. This should happen for 2 seconds when the key is turned on. I have tested this when the issue is occurring and have confirmed that no signal is being sent from the ECM.
The ECM controls the fuel pump relay and this relay will only energize when commanded on. Does the check engine light come on; if not, then the ECM is not turning on. Do all the other combination meter warning lights come on?
What should I do if there is no power in my fuel pump?
A test of the battery with a digital tester that provides current voltage, cold cranking amps, and state of health should be done first. The battery is the heart of the electrical system and if it stumbles or fails, it can affect all other systems.
What is the voltage of the fuel pump?
From the positive battery terminal to Pin 85 measured 10.9 V. The battery from terminal to terminal measured 12.2 V. Everywhere else I’ve compared voltage has been the same as the battery. That seems a little suspicious. I turned the key to On again and after about 3 or 4 seconds, the pump spontaneously primed.