Provide main or back-up protection against overload and overcurrents. Medium voltage current limiting and expulsion fuses suitable for the protection of distribution transformers, voltage transformers, capacitor banks, motor circuits and installations with other switching apparatus.
What are the different types of distribution fuses?
Classification for distribution fuses is defined by IEEE standard C37.47. Distribution fuses are farther from the substation, lower in voltage (2.8kV – 38kV) and have a lower X/R Rating. Cutouts and expulsion fuse links are an economical way to protect electrical distribution equipment.
How are fuses rated for a power system?
Fuses for commercial or industrial power systems must have higher interrupting ratings, with some low-voltage current-limiting high interrupting fuses rated for 300,000 amperes. Fuses for high-voltage equipment, up to 115,000 volts, are rated by the total apparent power (megavolt-amperes, MVA) of the fault level on the circuit.
How many currents does a general purpose fuse interrupt?
A general purpose fuse interrupts currents from the maximum interrupting rating, down to the current that causes the fuse element to melt in one hour. This is approximately 170% – 240% of the fuse rating. General purpose fuses do not include all the possible currents that the fuse may be required to clear.
Classification for distribution fuses is defined by IEEE standard C37.47. Distribution fuses are farther from the substation, lower in voltage (2.8kV – 38kV) and have a lower X/R Rating. Cutouts and expulsion fuse links are an economical way to protect electrical distribution equipment.
Why are distribution fuses farther from the substation?
Distribution fuses are farther from the substation, lower in voltage (2.8kV – 38kV) and have a lower X/R Rating. Cutouts and expulsion fuse links are an economical way to protect electrical distribution equipment. Different types of expulsion links can be inserted for use into a fuse holder.
When do utility fuses need to be used?
When a fuse detects an overcurrent (fault) that is higher than its designated rating, it will operate and open. Utility fuses are a necessity for applications such as the protecting equipment against violent failures, enhancing power quality, extending equipment life and limiting outages on the system.
A general purpose fuse interrupts currents from the maximum interrupting rating, down to the current that causes the fuse element to melt in one hour. This is approximately 170% – 240% of the fuse rating. General purpose fuses do not include all the possible currents that the fuse may be required to clear.